Version:2.4.1
NumericalData
ResourceID
spase://CNES/NumericalData/CDPP-AMDA/Cassini/RPWS/cass-rpws-neproxy
ResourceHeader
ResourceName
Cassini - RPWS - electron proxy
AlternateName
Langmuir Probe : electron proxy
ReleaseDate
2018-01-23 16:12:07Z
Description
Cassini RPWS Neproxy data contains all available RPWS Langmuir probe (LP) floating potentials and secondary products.
Cassini RPWS Langmuir Probe proxy electron density data are derived
using an empirical relation between the floating potential and CAPS
measured densities, for the entire mission. Spacecraft potential data
are also derived from LP floating potential.
Contacts
InformationURL
AccessInformation
RepositoryID
Availability
Online
AccessRights
Open
AccessURL
Name
CDPP/AMDA HAPI Server
URL
Style
HAPI
ProductKey
cass-rpws-neproxy
Description
Web Service to this product using the HAPI interface.
Format
CSV
Acknowledgement
Thank you for acknowledging the use of AMDA in publications with wording like "Data analysis was performed with the AMDA science analysis system provided by the Centre de Données de la Physique des Plasmas (CDPP) supported by CNRS, CNES, Observatoire de Paris and Université Paul Sabatier, Toulouse". See the Rules of the road at https://amda.cdpp.eu/help/policy.html . Please acknowledge the Data Providers.
AccessInformation
RepositoryID
Availability
Online
AccessRights
Open
AccessURL
Name
CDPP/AMDA Web application
URL
Description
Access to Data via CDPP/AMDA Web application.
Format
CSV
Format
VOTable
Format
CDF
Format
PNG
Acknowledgement
Thank you for acknowledging the use of AMDA in publications with wording like "Data analysis was performed with the AMDA science analysis system provided by the Centre de Données de la Physique des Plasmas (CDPP) supported by CNRS, CNES, Observatoire de Paris and Université Paul Sabatier, Toulouse". See the Rules of the road at https://amda.cdpp.eu/help/policy.html . Please acknowledge the Data Providers.
ProviderName
PDS
ProviderResourceName
CO-SS_S-RPWS-5-NEPROXY-V1.0
InstrumentIDs
MeasurementType
ThermalPlasma
TemporalDescription
TimeSpan
StartDate
2004-08-27 00:03:27Z
StopDate
2015-12-31 22:28:25Z
Cadence
PT640S
ObservedRegion
Saturn
Caveats
Occasional RPWS Langmuir probe voltage sweeps have interference in
individual sweep samples. These samples have been filtered away before
analysis and should not pose a problem for the delivered output
parameters. The Ufloat proxy method for this data set is applicable only
for densities below 5 cm^-3. To avoid uncertainty of the transition
region, data are limited to radial distance beyond 7 Rs from Saturn and
absolute magnetic latitude above 15 degrees. Also the data inside 10 Rt
from Titan are not included for the same reason. The proxy method uses
the photoelectron condition directly measured by the instrument and
therefore not available when LP is totally in shadow.
Parameter #1
Name
floating potential
ParameterKey
cass_neproxy_fpot
UCD
phys.potential;phys.electField;instr.obsty
Units
V
RenderingHints
Support
Parameter #2
Name
s/c potential
ParameterKey
cass_neproxy_scpot
UCD
phys.potential;phys.electField;instr.obsty
Units
V
RenderingHints
Support
Parameter #3
Name
density e-
ParameterKey
cass_neproxy_e
UCD
phys.density;phys.electron
Units
cm-3
RenderingHints
Particle
ParticleType
Electron
ParticleQuantity
NumberDensity