Version:2.4.1
NumericalData
ResourceID
spase://CNES/NumericalData/CDPP-AMDA/Cassini/RPWS/cass-rpws-saturn
ResourceHeader
ResourceName
Cassini - RPWS - electron proxy @ saturn
AlternateName
Langmuir Probe : electron proxy @ saturn
ReleaseDate
2018-01-23 18:01:52Z
Description
The Cassini RPWS Langmuir Probe Sweep @ Saturn data set contains thermal
plasma parameters derived from Langmuir Probe voltage sweeps
acquired in the vicinity of Saturn during the entire Cassini
mission. Data are the results of the Orbital Motion Limited analysis for each
calibrated sweep of the Langmuir probe receiver (LPR) of the RPWS
Contacts
InformationURL
AccessInformation
RepositoryID
Availability
Online
AccessRights
Open
AccessURL
Name
CDPP/AMDA HAPI Server
URL
Style
HAPI
ProductKey
cass-rpws-saturn
Description
Web Service to this product using the HAPI interface.
Format
CSV
Acknowledgement
Thank you for acknowledging the use of AMDA in publications with wording like "Data analysis was performed with the AMDA science analysis system provided by the Centre de Données de la Physique des Plasmas (CDPP) supported by CNRS, CNES, Observatoire de Paris and Université Paul Sabatier, Toulouse". See the Rules of the road at https://amda.cdpp.eu/help/policy.html . Please acknowledge the Data Providers.
AccessInformation
RepositoryID
Availability
Online
AccessRights
Open
AccessURL
Name
CDPP/AMDA Web application
URL
Description
Access to Data via CDPP/AMDA Web application.
Format
CSV
Format
VOTable
Format
CDF
Format
PNG
Acknowledgement
Thank you for acknowledging the use of AMDA in publications with wording like "Data analysis was performed with the AMDA science analysis system provided by the Centre de Données de la Physique des Plasmas (CDPP) supported by CNRS, CNES, Observatoire de Paris and Université Paul Sabatier, Toulouse". See the Rules of the road at https://amda.cdpp.eu/help/policy.html . Please acknowledge the Data Providers.
ProviderName
PDS
ProviderResourceName
CO-SS_S-RPWS-5-LPSWEEP-V1.0
InstrumentIDs
MeasurementType
ThermalPlasma
TemporalDescription
TimeSpan
StartDate
2004-12-14 00:02:06Z
StopDate
2016-01-30 16:04:08Z
Cadence
PT600S
ObservedRegion
Saturn
Caveats
Occasional RPWS Langmuir probe voltage sweeps have interference in
individual sweep samples. These samples have been filtered away
before analysis and should not pose a problem for the delivered
output parameters. The RPWS HFR receiver produces interference
signals in the LPR in certain negative bias voltage ranges. These do
not affect the analysis on the electron (positive bias voltage
side), and cause otherwise no significant error in the derived ion
parameters.
Thermal electron output data will usually not be available, due to
photoelectron current contamination, for number densities below 1
cm^-3 and/or for temperatures above 10eV, i.e. outside the
ionosphere of Titan. Data < 1 cm^-3 and/or > 10 eV should be
regarded as uncertain. Electron temperatures below 0.03eV should be
regarded as uncertain, as the rms electric field surface variability
of the spherical TiN coated probes is 0.015eV, and the number of
sweep samples used for the temperature estimation becomes small (4-5
samples out of 1024 samples over +/-4V).
Parameter #1
Name
distance cassini-saturn
ParameterKey
cass_saturn_radius
UCD
pos.distance;instr.obsty
Units
Titan radius
RenderingHints
Support
SupportQuantity
Positional
Parameter #2
Name
density e-
ParameterKey
cass_saturn_density
UCD
phys.density;phys.atmol.ionStage
Units
cm-3
RenderingHints
Particle
ParticleType
Electron
ParticleQuantity
NumberDensity
Parameter #3
Name
temperature e-
ParameterKey
cass_saturn_temperature
UCD
phys.temperature;phys.atmol.ionStage
Units
eV
Particle
ParticleType
Electron
ParticleQuantity
Temperature
Parameter #4
Name
s/c potential
ParameterKey
cass_saturn_scpot
UCD
phys.potential;phys.electField;instr.obsty
Units
V
RenderingHints
Support