HDPWS

MMS1 - EDP - burst - dc e-field

ResourceID
spase://CNES/NumericalData/CDPP-AMDA/MMS/MMS1/EDP/mms1-dce-brst

Description
Electric Double Probe, Three-Dimensional Electric Field, Level 2, Burst Mode Data

View XML | Edit

Details

Version:2.4.1

NumericalData

ResourceID
spase://CNES/NumericalData/CDPP-AMDA/MMS/MMS1/EDP/mms1-dce-brst
ResourceHeader
ResourceName
MMS1 - EDP - burst - dc e-field
AlternateName
dc electric field / burst / l2
ReleaseDate
2024-08-12 16:48:36Z
Description
Electric Double Probe, Three-Dimensional Electric Field, Level 2, Burst Mode Data
Contacts
Role Person StartDate StopDate Note
1. PrincipalInvestigator spase://SMWG/Person/James.L.Burch
2. PrincipalInvestigator spase://SMWG/Person/Robert.E.Ergun
3. PrincipalInvestigator spase://SMWG/Person/Per-Arne.Lindqvist

InformationURL
Name
MMS home page at GSFC
URL
InformationURL
Name
Science Data Center at LASP
URL
Association
AssociationID
AssociationType
PartOf
Note
burst
AccessInformation
RepositoryID
Availability
Online
AccessRights
Open
AccessURL
Name
CDPP/AMDA HAPI Server
URL
Style
HAPI
ProductKey
mms1-dce-brst
Description
Web Service to this product using the HAPI interface.
Format
CSV
Acknowledgement
Thank you for acknowledging the use of AMDA in publications with wording like "Data analysis was performed with the AMDA science analysis system provided by the Centre de Données de la Physique des Plasmas (CDPP) supported by CNRS, CNES, Observatoire de Paris and Université Paul Sabatier, Toulouse". See the Rules of the road at https://amda.cdpp.eu/help/policy.html . Please acknowledge the Data Providers.
AccessInformation
RepositoryID
Availability
Online
AccessRights
Open
AccessURL
Name
CDPP/AMDA Web application
URL
Description
Access to Data via CDPP/AMDA Web application.
Format
CSV
Format
VOTable
Format
CDF
Format
PNG
Acknowledgement
Thank you for acknowledging the use of AMDA in publications with wording like "Data analysis was performed with the AMDA science analysis system provided by the Centre de Données de la Physique des Plasmas (CDPP) supported by CNRS, CNES, Observatoire de Paris and Université Paul Sabatier, Toulouse". See the Rules of the road at https://amda.cdpp.eu/help/policy.html . Please acknowledge the Data Providers.
ProviderName
LASP
InstrumentIDs
MeasurementType
ElectricField
TemporalDescription
TimeSpan
StartDate
2015-08-02 00:03:44Z
StopDate
2024-06-15 17:46:03Z
Cadence
PT0.00015S
Caveats
Quality indicator ( dce : qual ) * 3 - good * 2 - ok data, use with some caution * 1 - bad data, use with caution * 0 - really bad data or no data at all
Parameter #1
Name
e_gse
ParameterKey
mms1_dce_gse_brst
Units
mV/m
CoordinateSystem
CoordinateRepresentation
Cartesian
CoordinateSystemName
GSE
RenderingHints
DisplayType
TimeSeries
Structure
Size
3
Element
Name
ex
Qualifier
Component.I
Index
1
ParameterKey
mms1_dce_gse_brst(0)
Element
Name
ey
Qualifier
Component.J
Index
2
ParameterKey
mms1_dce_gse_brst(1)
Element
Name
ez
Qualifier
Component.K
Index
3
ParameterKey
mms1_dce_gse_brst(2)
Field
Qualifier
Vector
FieldQuantity
Electric
Parameter #2
Name
e_gsm
ParameterKey
mms1_dce_gsm_brst
Units
mV/m
CoordinateSystem
CoordinateRepresentation
Cartesian
CoordinateSystemName
GSM
RenderingHints
DisplayType
TimeSeries
Structure
Size
3
Element
Name
ex
Qualifier
Component.I
Index
1
ParameterKey
mms1_dce_gsm_brst(0)
Element
Name
ey
Qualifier
Component.J
Index
2
ParameterKey
mms1_dce_gsm_brst(1)
Element
Name
ez
Qualifier
Component.K
Index
3
ParameterKey
mms1_dce_gsm_brst(2)
Field
Qualifier
Vector
FieldQuantity
Electric
Parameter #3
Name
dce : qual
ParameterKey
mms1_dce_qual_brst
Description
Quality indicator (3 good), (2 ok data, use with some caution), (1 bad data, use with caution), (0 Really bad data or no data at all)
RenderingHints
DisplayType
TimeSeries
Support
SupportQuantity
DataQuality