Version:2.4.0
NumericalData
ResourceID
spase://CNES/NumericalData/CDPP-Archive/ROSETTA/RPC_MIP/ROSETTA_RPC_MIP_S5DXX
ResourceHeader
ResourceName
ROSETTA RPC-MIP Plasma Electron Density (CDF)
DOI
https://doi.org/10.24400/802406/37pc-qytv
ReleaseDate
2022-05-30 17:42:31Z
Description
This dataset contains the plasma electron density derived from electric field mutual impedance spectra obtained by on-ground analysis of RPC-MIP spectra acquired when RPC-MIP operated in active modes (SDL and LDL).
Acknowledgement
Please acknowledge the Principal Investigator(s), the RPC-MIP Team, the ESA Planetary Science Archive as well as the CDPP (Centre de Données de la Physique des Plasmas) for the provision of these data when making a publication using these data.
Principal Investigator(s) : P. Henri (LPC2E/CNRS, Orléans, France)
Contacts
AccessInformation
RepositoryID
Availability
Online
AccessURL
Name
REGARDS
URL
Description
Access via CNES Data Archive for CDPP
Format
CDF
ProcessingLevel
Calibrated
InstrumentIDs
MeasurementType
InstrumentStatus
TemporalDescription
TimeSpan
StartDate
2014-08-07 00:00:00Z
StopDate
2016-09-30 00:00:00Z
ObservedRegion
Comet
Parameter #1
Name
delta_time
Description
Each RPCMIP measurement is acquired and averaged on-board during a certain duration. DELTA_TIME is half the acquisition duration
Units
s
Support
Parameter #2
Name
Electron Density
Description
Plasma electron density
Units
cm^-3
UnitsConversion
1.0e6>m^-3
Particle
ParticleType
Electron
ParticleQuantity
NumberDensity
Parameter #3
Name
Electron density uncertainty
Description
Estimated uncertainty of the plasma electron density
Units
cm^-3
UnitsConversion
1.0e6>m^-3
Support
Qualifier
Uncertainty
SupportQuantity
Other
Parameter #4
Name
SNR Quality
Description
Local quality of the plasma frequency signature in the spectrum between 0 (worst quality) and 1 (best quality) see RPCMIP User Guide for more details
Support
SupportQuantity
DataQuality
Parameter #5
Name
Spectrum quality
Description
Quality describing the spectrum complexity between 0 (worst quality) and 1 (best quality) see RPCMIP User Guide for more details
Support
SupportQuantity
DataQuality
Parameter #6
Name
Density detection rate
Description
Density detection rate in a 320 sec (10 operation cycles) window centered on the considered density value between 0 (worst quality) and 1 (best quality) see RPCMIP User Guide for more details
Support
Parameter #7
Name
Instrument mode
Description
Instrument mode at the time of acquisition (LDL, SDL)
Support
SupportQuantity
InstrumentMode
Parameter #8
Name
Instrument Transmission Lavel
Description
Instrument transmission level (Full, 1/2, 1/4, 1/8)
Support
SupportQuantity
InstrumentMode
Parameter #9
Name
Instrument telemetry rate
Description
Instrument telemetry rate (Normal rate, Burst rate)
Support
SupportQuantity