CDF data of magnetic field measured at 20Hz intervals with the induction magnetometer at Syowa Station, Antarctica.

ResourceID
spase://IUGONET/NumericalData/NIPR/UAPM/SYO/induction/PT005S_cdf

Description
Magnetic field measured with the induction magnetometer at Syowa Station, Antarctica. The data consist of variations of three-dimensional (H, D, and Z components) geomagnetic field taken with a sampling rate of 20 Hz, and some engineering parameters for the instrument, such as the sensitivity and phase difference. (As of July 2013, the engineering parameters are invalid.) The digital data are distributed in the Common Data Format (CDF).

View XML | Edit

Details

Version:2.5.0

NumericalData

ResourceID
spase://IUGONET/NumericalData/NIPR/UAPM/SYO/induction/PT005S_cdf
ResourceHeader
ResourceName
CDF data of magnetic field measured at 20Hz intervals with the induction magnetometer at Syowa Station, Antarctica.
ReleaseDate
2013-07-09 12:00:00
Description
Magnetic field measured with the induction magnetometer at Syowa Station, Antarctica. The data consist of variations of three-dimensional (H, D, and Z components) geomagnetic field taken with a sampling rate of 20 Hz, and some engineering parameters for the instrument, such as the sensitivity and phase difference. (As of July 2013, the engineering parameters are invalid.) The digital data are distributed in the Common Data Format (CDF).
Acknowledgement
Please contact the Principal Investigator, Dr. Hisao Yamagishi (yamagisi [at] nipr.ac.jp), National Institute of Polar Research (NIPR) before using the data at any publications and/or presentations. We welcome collaborative research and strongly recommend users to contact us early in order to ensure that the data are suitable for their research. When the data are used at any publications and/or presentations, we would like to ask the users to acknowledge NIPR and send us one copy of the reprints. An example of the acknowledgement statement is as follows: 'Magnetic field data were provided by National Institute of Polar Research, Japan. The Upper Atmosphere Physics Monitoring Observation at Syowa Station was mainly supported by the Research Program of Japanese Antarctic Research Expedition (JARE) of the Ministry of Education, Culture, Sports, Science, and Technology of Japan (MEXT).' For more details about the observations, please refer the following data report: JARE data reports. Upper atmosphere physics 26, 1-59, 2008-02.
Contacts
Role Person StartDate StopDate Note
1. PrincipalInvestigator spase://IUGONET/Person/Hisao.Yamagishi
2. MetadataContact spase://IUGONET/Person/Yuka.Sato

AccessInformation
RepositoryID
Availability
Online
AccessRights
Open
AccessURL
Name
Upper Atmosphere Physics Monitoring Observation at Syowa Station
URL
AccessURL
Name
Conjugate Observation between Syowa Station and Iceland
URL
AccessURL
Name
IUGONET Database in NIPR
URL
Format
CDF
ProcessingLevel
Uncalibrated
InstrumentIDs
MeasurementType
MagneticField
TemporalDescription
TimeSpan
StartDate
1998-02-01 00:00:00
RelativeStopDate
-P90D
Cadence
PT0.05S
ObservedRegion
Earth.Magnetosphere
ObservedRegion
Earth.NearSurface.Ionosphere.ERegion
SpatialCoverage
CoordinateSystem
CoordinateRepresentation
Spherical
CoordinateSystemName
GEO
NorthernmostLatitude
-69.00
SouthernmostLatitude
-69.00
EasternmostLongitude
39.58
WesternmostLongitude
39.58
Keywords
EARTH SCIENCE Sun-earch Interaction Ionosphere/Magnetosphere Dynamics Magnetic Fields/Magnetic Currents
Parameter #1
Name
Epoch for the dB/dt data
ParameterKey
epoch_db_dt
Description
time label in CDF_EPOCH (the number of milliseconds since 01-Jan-0000) for the dB/dt data. All time values are in the universal time.
Units
millisecond
Support
SupportQuantity
Temporal
Parameter #2
Name
Observation date and time for the dB/dt data
ParameterKey
time_db_dt
Description
Observation date and time for the dB/dt data. The time label for each time frame consists of an integer array of 7 elements for Year, month, day, hour, minute, second, milisecond. All time values are in the universal time.
Support
SupportQuantity
Temporal
Parameter #3
Name
dB/dt values for 3-component vector magnetogram
ParameterKey
db_dt
Description
Time derivative of 3-component (dH/dt, dD/dt, and dZ/dt) vector geomagnetic field observed with a sampling rate of 20 Hz. The unit is voltage [V], that is, the raw output from the instrument.
Field
FieldQuantity
Magnetic
Parameter #4
Name
Pulse signal from the GPS clock associated with the magnetometer
ParameterKey
gps_1pps_time_pulse
Description
This parameter is invalid for this data.
Support
SupportQuantity
Other
Parameter #5
Name
Frequency values for the sensitivity-phase difference table
ParameterKey
frequency
Description
Frequency values in Hz for the sensitivity-phase difference table for this induction magnetometer. As of July 2013, this parameter is invalid.
Support
SupportQuantity
Other
Parameter #6
Name
Sensitivity coefficients for the sensitivity-phase difference table
ParameterKey
sensitivity
Description
Conversion coefficients in V/nT taking into account the frequency-dependent sensitivity for this induction magnetometer. As of July 2013, this parameter is invalid.
Support
SupportQuantity
Other
Parameter #7
Name
Phase difference values for the sensitivity-phase difference table
ParameterKey
phase_difference
Description
Phase difference in degree for each frequency used for the phase calibration. As of July 2013, this parameter is invalid.
Support