ResourceName
Polar Electric Fields Instrument (EFI), Spacecraft Potential and Plasma Density, Realtime Resolution
ReleaseDate
2020-07-07 21:15:01Z
Description
This data consists of the Spacecraft Potential and the Plasma Density, at spacecraft realtime resolution, where the Plasma Density is obtained as a function, provided by Dr. Jack Scudder, the PI of the POLAR Hydra investigation. This function was determined by a fit to the POLAR Hydra particle data for 2001/04/01. The relative accuracy of the Plasma Density, estimated from the spacecraft potential on short time scales is ~10-30% depending on plasma conditions. The absolute accuracy is better than a factor of two for densities less than about 20 particles/cm^3. Density values greater than 30 particles/cm^3 are not plotted because they are inaccurate due to the steep slope of the curve of density versus spacecraft potential. If the value of the argument to the function is too large, then the Plasma Density is set to a filler value of 1.0e+20. Also, if the value returned by the function is too large, then the result is not reliable, and therefore the Plasma Density is set to a filler value of 1.0e+20. If the value of the argument to the function is too small, then the Plasma Density is set to a filler value of 1.0e-20. So, a value of the Plasma Density is a filler value if and only if it is either larger than 1.0e+2 (100.0) or smaller than 1.0e-4 (0.0001); otherwise, it is a true value. Note that all values of the Spacecraft Potential are true values. There is no filler.
Acknowledgement
The user will acknowledge, in any publication which uses POLAR EFI data, the instrument PI, as well as the instrument PI for the POLAR Hydra instrument, if the Plasma Density is used.
Contacts
PriorIDs
spase://VWO/NumericalData/POLAR/EFI/SC_Potential_PlasmaDensity_Realtime
spase://VSPO/NumericalData/POLAR/EFI/SC/Potential_PlasmaDensity/Realtime/PT6S
RepositoryID
Availability
Online
AccessRights
Open
AccessURL
URL
Description
This URL is the root location of the POLAR EFI archive. It consists of Yearly subdirectories: 1996, 1997, ..., 2008 each of which consists of Monthly subdirectories: 01, 02, ..., 12 The archive files for a given date are located in the corresponding YY/MM subdirectory.
Language
en
Format
CDF
Encoding
None
Acknowledgement
The user will acknowledge, in any publication which uses POLAR EFI data, the instrument PI, as well as the instrument PI for the POLAR Hydra instrument, if the Plasma Density is used.
Name
Time
ParameterKey
TIME_TAG
Description
Data point time-tags which are double precision floating point numbers which represent the number of seconds, UTC, from midnight of the day represented by the file.
Cadence
PT6S
Units
seconds
ValidMin
0.0
ValidMax
86460.0
Support
Name
PlasmaDensity
ParameterKey
DATA_VALUES
Description
Data point value which represents the Plasma Density as single precision floating point numbers. Not all times in the TIME_TAG parameter correspond to true PlasmaDensity data, so there are filler values.
Cadence
PT6S
Units
Particles/cm^3
ValidMin
0.0001
ValidMax
100.0
FillValue
1.0e+20,1.0e-20
Field
Qualifier
Scalar
FieldQuantity
PlasmaFrequency